3 IN 1 Ultra adhesive


DESCRIPTION

3 IN 1 Ultra is a one component, 100% solids, cross-linking, MS polymer based adhesive.  Formulated for interior installations of engineered hardwood products and mineral core products.

3 IN 1 Ultra can be used as a moisture control adhesive for engineered wood products only, when applied with the appropriate trowel that is supplied in the adhesive pail. 

APPROVED SUBSTRATES

  • For interior use only.

  • Wood Association approved wood underlayment and subflooring. See Resilient Wood Substrate Information Sound and properly prepared concrete (on, above or below grade), metal, wood fiberglass and terrazzo.

  • Concrete must be at least 45 days old prior to apply 3 IN 1 Ultra adhesive.

  • Existing resilient products should be over 1 year old, secure and fully adhered with a full spread of adhesive. Remove all waxes and polishes from the existing floor before installation.

SUBSTRATE TESTING

3 IN 1 Ultra adhesive does not react to moisture and does not have moisture limits or pH limits associated with the adhesive.

3 IN 1 Ultra is approved for mineral core flooring and engineered wood flooring.  Per the installation guidelines for each product, moisture testing and pH testing must be performed, product limits are listed below.

Flooring Type

RH (ASTM F2171)

CaCl (ASTM F1869)

Alkalinity

Mineral Core

90% (absent of hydrostatic pressure)

8 lbs (MVER)

5-12

Engineered Wood

75% (absent of hydrostatic pressure)

3 lbs (MVER)

5-12

 
For older slabs or slabs with a prior history of moisture related issues, Shaw Technical Support recommends moisture mitigation in the form of a 2-part epoxy system, such as MoistureTEK.
For newer slabs with an intact moisture retarder, initial moisture levels should recede over time.

NOTE:  For engineered wood installations only, by using the 3/16” x 1/4” x 1/2” flat v notch trowel with spacers, moisture and pH testing is not required. 

SUBSTRATE PREPARATION

  • Substrate must be structurally sound, clean, level and dry.

  • Substrate must be free of dust, dirt, oil, grease, paint, curing agents, concrete sealers, adhesives, loosely bonded toppings, loose particles and any other substance or condition that may prevent or reduce adhesion.

  • Do not use over substrates containing asbestos or active cutback adhesive.

  • Fill depressions or cracks with a cementitious patching / leveling compound that meet or exceed Shaw Industries maximum moisture level and pH requirements. Use of gypsum-based patching and/or leveling compounds which contain Portland or high alumina cement and meet or exceed the compressive strength of 3,000 psi are acceptable.

  • For cracks and saw cuts deeper that 1”, Shaw QuickFil is recommended.

  • Installation site must be acclimated with HVAC in operation or the temperature must be controlled between 65-95O F (18- 35O C) and the ambient relative humidity controlled between 30-65% before, during and permanently after the installation.

  • Do not use over chemically abated substrates.

APPLICATION INSTRUCTIONS AND SPREAD RATES FOR MINERAL CORE FLOORING

Read and follow the product specific installation guidelines for layout, design and any special instructions for installation.

  • Spread adhesive using the recommended trowel.

  • Spread adhesive evenly over substrate, keeping the trowel at a 45° angle to the substrate.

  • Once the adhesive is spread, immediately install the floor covering into the wet adhesive.

Flooring Type

Trowel Size

Coverage

Mineral Core

1/8” x 1/8” x 1/8” U-notch

60-70 ft2/gal

 
After installation of floor covering, roll floor covering with a 75 – 100 lb roller.

Cure Time

24 Hours

 
Note:  Actual jobsite coverages may vary according to substrate conditions, type of trowel used and setting practices. Trowel dimensions are width/depth/space. 

APPLICATION INSTRUCTIONS AND SPREAD RATES FOR ENGINEERED WOOD FLOORING

Read and follow the product specific installation guidelines for layout, design and any special instructions for installation.

  • Spread adhesive using the recommended trowel.

  • Spread adhesive evenly over substrate, keeping the trowel at a 45° angle to the substrate.

  • Once the adhesive is spread, immediately install the floor covering into the wet adhesive.

Flooring Type

Trowel Size

Coverage

Engineered Products 3/8” to ½” thick

3/16” x 1/4” x 5/16” flat v notch

50-60 ft2/gal

Engineered products ¼” thick

1/8” x 1/8” x 1/8” square-notch

Up to 80 ft2/gal

For Moisture and Sound plus Wood installation applications (see note below referencing spacer wear)

3/16” x 1/4” x 1/2” flat v notch with spacers

30-35 ft2/gal

 
After installation of floor covering, roll floor covering with a 75 – 100 lb roller.

Cure Time

24 Hours

 
Note:   Actual jobsite coverages may vary according to substrate conditions, type of trowel used and setting practices.

Trowel dimensions are width/depth/space.

Due to spacer wear, replace the included trowel blade for every pail of LokWorx Multi-Use 3 IN 1 Ultra adhesive.

ADHESIVE APPLICATION NOTES

  • Coverage is approximate and will vary depending on porosity and roughness of the subfloor, angle at which the trowel is held, temperature of the adhesive and the subfloor, and the skill of the installer applying the adhesive.

  • Coverage can be lower over subfloors not properly prepared according to established industry guidelines.  

PRODUCT CHARACTERISTICS

Read and follow the product specific installation guidelines for layout, design and any special instructions for installation.

Weight

44 lbs / 4 gallon pail

Pallet Quantity

48

Pallet Weight

2,162 lbs

Polymer Type

MS Polymer

Percent Solids

100%

VOC’s (Rule #1168 of California SCAQMD)

.5 g/L

Color

Off White

Shelf Life

1 years from manufacturing date, in an unopened container

Storage Conditions

50oF to 90oF (15oC to 328oC).  Protect from freezing

Flash point (ASTM D56)

>212oF / 100oC

Cleaning Instructions

Use warm soapy water while adhesive is still wet. 

Traffic

Light Traffic – 12 hours
Heavy Traffic - 24 hours

 

Environmental

LEED IEQ Credit Information (2009 and V4)

Credit Requirement

Status

Comment

Meets General Emissions Evaluation Criteria

Complies

CRI Green Label Plus (GLP) #100938

VOC’s (Rule #1168 of California SCAQMD amended October 6, 2017)

Complies

VOC Content < 50 g/L

WARRANTY

This product is covered by a 1 year limited warranty and 15 Year under bed warranty when used with specific products. For more detailed information on this limited warranty, please see contact information at the bottom of this page

Revision: 02122023
Tech Services 1-800-471-7429